Modulus Onnerandi Liquidi Refrigerandi 40kW DC pro Statione Onnerandi 600kW 720kW DC
TECHNOLOGIA PROFECTA
Hic Modulus Impletionis Refrigerationis Liquidae LRG1K0135G 40kW modum duplicem input DC et DC sustinet, qui impletionem accumulatoris per rete electrica et impletionem vehiculi per accumulatorem coniungit. Simul, requisitis magnitudinis trium modulorum unificatorum State Grid satisfacit.
Alta Efficacia et Conservatio Energiae
Lata constans potentiae output amplitudo
Consumptio energiae in modo exspectato infima
Temperatura operandi ultra-lata
AMPLIUS AMPLIUS TENSIONIS EMISSIONIS
COMPATIBILIS CUM OMNIBUS REQUISITIS CAPACITATIS BATTERIAE VEHICULI ELEVITRICIS
Latissima gamma emissionis 50-1000V, conveniens generibus curruum in foro et accommodans ad currus electricos altae tensionis in futuro.
● Modulus potentiae refrigerationis liquidi REG1K0135. Compatibilis cum suggestu existente 150V-1000Vdc et plenam potentiam impletionis pro futuro progressu supra 1000V praebet, quod investitionem in constructionem emendationis impletionis vehiculorum electricorum altae tensionis vitare potest.
● CCS1, CCS2, CHAdeMO, GB/T et systemata accumulationis energiae sustinet.
● Modulus onerationis refrigerationis liquidi REG1K0135 Futurae inclinationi onerationis altae tensionis vehiculorum electricorum occurre, cum variis applicationibus onerationis et generibus curruum congruens.
INTELLIGENS MODERATIO PRO TUTO ET
MODULUS IMPLETIONIS FIDUCIABILIS
Specificationes
| 40KW REG1K0135 Refrigeratio Liquida Modulus Implendi | ||
| Numerus exemplaris | REG1K0135 | |
| Introitus AC | Aestimatio Input | 260Vac ~ 530Vac, triphasis + Terra Protectiva |
| Nexus Ingressus AC | 3L + PE | |
| Frequentia Input | 50/60±5Hz | |
| Factor Potentiae Ingressae | ≥0.99 | |
| Protectio Supertensionis Ingressus | 490±10Vac | |
| Protectio Subtensionis Ingressus | 270±10Vac | |
| Egressus DC | Potentia Producta Aestimata | 20kW |
| Ambitus Tensionis Egressus | 150Vdc ~ 1000Vdc | |
| Ambitus Currentis Egressus | 0.5-67A | |
| Potentia Constans Emissionis | Cum tensio emissa est 150-1000Vdc, constans 30kW emittetur. | |
| Efficacia Maxima | ≥ 96% | |
| Tempus Initii Mollis | 3-8s | |
| Protectio Circuitus Brevis | Protectio ab auto-reversione | |
| Accuratio Regulationis Tensionis | ≤±0.5% | |
| THD | ≤5% | |
| Accuratio Regulationis Currentis | ≤±1% | |
| Inaequalitas Communicationis Praesentis | ≤±5% | |
| Operatio Ambitus | Temperatura Operandi (°C) | -40˚C ~ +75˚C, deminutione temperaturae a 55˚C |
| Humiditas (%) | ≤95% RH, non condensans | |
| Altitudo (m) | ≤2000m, deminutione potentiae supra 2000m | |
| Methodus refrigerationis | Refrigeratio ventilabri | |
| Mechanica | Consumptio Energiae in Tempore Requiescenti | <10W |
| Protocollum Communicationis | POSSUM | |
| Constitutio Inscriptionis | Ostentatio digitalis in schermo, operatio clavium | |
| Dimensio Moduli | 460*218*84mm (L*A*A) | |
| Pondus (kg) | ≤ 13 kg | |
| Protectio | Protectio Ingressus | OVP, OCP, OPP, OTP, UVP, praesidium contra impetus |
| Protectio Egressus | SCP, OVP, OCP, OTP, UVP | |
| Insulatio Electrica | Egressus DC et ingressus AC insulati | |
| MTBF | Horae quingentae milia | |
| Regulatio | Certificatum | UL2202, IEC61851-1, IEC61851-23, IEC61851-21-2 Classis B |
| Salus | CE, TUV | |
Proprietates principales
Modulus oneris REG1K0135 40kw DC est modulus potentiae internus pro stationibus oneris DC (palis), et energiam AC et DC in DC convertit ad vehicula oneranda. Modulus oneris input currentis triphasici accipit et deinde tensionem DC ut 150VDC-1000VDC emittit, cum output DC adaptabili ad varia requisita fasciculi accumulatoris implenda.
Modulus onerandi liquidi refrigerationis 40kW DC REG1K0135 instructus est functione POST (auto-probationis potentiae), protectione contra super/sub tensionem in ingressu AC vel DC, protectione contra super tensionem in egressu, protectione contra temperaturam excessivam, et aliis proprietatibus. Usoribus licet plura modula onerandi paralleliter cum uno armario potentiae coniungere, et pollicemur nostros oneratores EV multiplices coniungere valde certos, aptos, efficaces, et minimam curam requirere.
REG75035 20kw 750V Triphasicum
REG75050 20kw 750V Triphasicum
REG75050A 20kw 750V Triphasicum
REG1K0100 30kw Triphasicum
REG75020S 7kw AC DC
CEG75050 20kw DC DC
HEG75050 20kw
BEC75025 15kw
BEC1K0135G 40kW DC DC
BEC900280G 150kW DC DC
BSG1K037G V2G 11kW
BEG75050 15kW V2G
BEG1K075 22kW V2G AC DC
REG1K0135A2 Modulus Implendi AC/DC 30kw
BEG1K0110G Modulus Infypower 62.5KW Modulus Implendi
REG1K0100A2 Modulus Potentiae AC DC 30kw ad Stationem Celerem DC Impletionis
BEG1K0110G Modulus Potentiae Conversoris Bidirectionalis AC DC 62.5kW pro Statione Onnerandi DC
LBG1K0120G Modulus Potentiae Conversoris Bidirectionalis AC DC 35kW
LRG1K0135G Modulus Rectificatorius 40KW 1000V AC DC Modulus Onnerans EV
LCG1K0135G Modulus Conversor DC DC 40KW 1000V Modulus Impletionis Vehiculorum Electricorum (EV)
REG1K070 Modulus Impletionis Vehiculorum Electricorum 20kw Modulus Potentiae AC DC
REG1K0100A2 Modulus Potentiae AC DC 30kw ad Stationem Celerem DC Impletionis
BEG1K0100 Modulus Impletionis Vehiculorum Electricorum 30kW Modulus Potentiae AC DC
REG1K0135 Modulus Potentiae 40kw pro Statione Impletionis Liquore Refrigerata
Infypower CEG1K0100G 30kw MPPT DC DC Modulus Potentiae ad Accumulatorem Solarem Implendum
Commoda
Optiones Plures
Alta potentia ut REG1K0135Modulus Refrigerationis Liquidae 40KW Modulus Implendi
Tensio egressa usque ad 1000V
Alta Fiducia
- Monitorium temperaturae generale
- Defensiones contra humiditatem, nebulam salinam et fungos
- MTBF > 100,000 horae
Securus et Tutus
Lata amplitudo tensionis ingressus 270~480V AC
Lata temperaturae operandi amplitudo -30°C ~ +50°C
Consumptio Energiae Parva
Modus somni unicus, potentia minus quam 2W
Alta efficientia conversionis usque ad 96%
Modus parallelus intelligens, optima efficacia operans
Applicationes
1, Moduli oneratorii DC 40kw REG1K013540 kWIn stationibus celeris onerationis DC pro vehiculis electricis et autobusibus electricis adhiberi potest.
2, modulus oneris REG1K0135 40KW AC DC munitus est praesidio contra supertensionem in ingressu, alarmum contra deminutionem tensionis, supercurrentiam in egressu, et praesidium contra circuitum brevem. Moduli oneris in systemate parallelo coniungi possunt, quod permutationem calidam et faciliorem sustentationem permittit. Hoc etiam applicabilitatem et firmitatem systematis praestat.
3, Modulus bidirectionalis oneratoris REG1K0135 40KW est modulus potentiae internus pro stationibus oneratoriis DC (palis), et energiam AC in DC convertit ad vehicula oneranda. Modulus oneratoris input currentis triphasici accipit et deinde tensionem DC ut 200VDC-500VDC/300VDC-750VDC/150VDC-1000VDC emittit, cum output DC adaptabili ad varia requisita fasciculi accumulatoris implenda.
4, Modulus oneris REG1K0135 40KW instructus est functione POST (auto-probationis potentiae), protectione contra super/sub tensionem AC in ingressu, protectione contra super tensionem in egressu, protectione contra temperaturam excessivam, aliisque functionibus. Usoribus licet plures modulos oneris paralleliter cum uno armario fontis potentiae coniungere, et nos spondemus nostros oneros EV multiplices coniungere esse valde certos, aptos, efficaces, et minimam curam requirere.
Modulus Potentiae Onnerans Vehiculi Electrici (EV) 5,1000V 40kW DC DC REG1K0135 Statio Onnerans Celeris EV 40KW. Modulus onerandi 40kw, rectificator EMC 1000v classis B, modulus potentiae onnerans EV.
Caricator portatilis vehiculorum electricorum
Arca Muralis Vehiculi Electrici Domestici
Statio Onnerandi DC
Modulus Impletionis Vehiculorum Electricorum (EV)
NACS et CCS1 et CCS2
Accessiones Vehiculorum Electricorum












