banner_remusoro

Chaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubs

Chaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubs

MIDA Power iri kutsanangura patsva zvivakwa zvemagetsi emagetsi neChaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubs, mhinduro yekuchaja ye180kW yepamusoro-soro.

I. Advanced Hardware Topology: SiC MOSFETs uye LLC Resonant Converters

Iyo MIDAChaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubsyakagadzirwa nemagetsi ane simba remagetsi rinotenderera zvakanyanya. TakabatanidzaSilicon Carbide (SiC) MOSFETskutsiva maSilicon IGBT echinyakare, zvichiita kuti kurasikirwa kwekuchinjana kuderedzwa ne30%.180kWkugadzirwa kwezvinobuda, izvi zvinoguma nekushanda kwepamusoro kwe96.5%.Chishanduri cheLLC Resonantmagadzirirwo ezvivakwa anogonesa Zero Voltage Switching (ZVS), zvichiita kuti kupisa kugadzikane kunyangwe panguva yekushanda kwenguva refu kwesimba remagetsi pa180kW. Izvi zvakakosha kumapuratifomu emagetsi e1000V, zvichibvumiraChaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubskuchaja maEV echizvarwa chinotevera nemazvo zvakanyanya.

Chaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubs

Kutarisirwa kwekupisa kunotungamirirwa kuburikidza nehurongwa hweMIDA hwakasiyana hwemhepo. Mamodule emagetsi anogara muchiteshi chekutonhodza chakatsaurirwa, chakaparadzaniswa nemadziro elogic. Izvi zvinodzivirira kuungana kweguruva uye zvinoita kuti IP55 ive chiyero chehupenyu hurefu hwekunze.

II. AI-DES v4.0: Iyo Intelligence Layer

IyoChaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubsine gateway yeAI-DES (AI-Dynamic Energy Scheduling) v4.0. Sisitimu iyi inoshanda muzvikamu zvitatu: Grid-Edge Responsiveness (10kHz sampling), Vehicle-Specific Profile (ISO 15118), uye Economic Load Balancing. Kune nzvimbo dzine akawanda180kWNekushandisa mayuniti, sisitimu yeAI-DES inoita basa rekugera nekukurumidza panguva chaiyo, ichiva nechokwadi chekuti mutoro wenzvimbo yese haumbopfuuri miganhu yechibvumirano ukuwo ichipa mota dzine State-of-Charge yakaderera (SoC).

III. Ongororo yeRoI yeMabhizinesi uye TCO Metrics

Kune CPO, iyoChaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubsinomiririra pfuma ine goho guru. Nekushanda zvakanaka kwe96.5%,180kWChiteshi chine simba re300,000 kWh pagore chinochengetedza simba rinodarika 15,000 kWh kana tichienzanisa nemidziyo yemagetsi yakajairwa muindasitiri. Izvi zvinoreva kuti OPEX inochengetedza mari inosvika $2,250 pagore (@$0.15/kWh).

Chiyero Mwero weIndasitiri (91%) MIDA 180kW (96.5%)
Kupisa Simba Marara 27,000 kWh 10,500 kWh
Kubudirira Kunobudirira Nheyo yekutanga Kuvandudzwa kwe5.5%
Hupenyu hweKushanda (MTBF) Maawa zviuru makumi mashanu Maawa 92,000

IV. Kuisa SOP uye Kutevedzera Mutemo Wenyika Yose

KuisaChaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubsinotevedzera MIDA SOP yakasimba. Zvinodiwa zvinosanganisira hwaro hwekongiri hwakasimbiswa neC30-grade, dziviriro yeSPD Class II surge, uye kudzivirira pasi pasi pe4 Ohms. Chiteshi ichi chine chitupa chakazara pasi peCE (IEC 61851), UL 2202, uye CHAdeMO 2.0.1 chekushanda pamwe chete kwepasi rose.

Uyezve, gwara reMIDA Power ra2026 rinosimbisa shanduko kuenda kuV2G (Mota-kuenda-kuGrid) uye MCS (Megawatt Charging Systems).Chaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubshazvizombofi zvakamira mune ramangwana, zvichibvumira kuti simba rifambe munzira mbiri kuti ritsigire kugadzikana kwegrid. Nekuchengetedza simba mumapaketi emabhatiri engarava,Chaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubsinoshanda senzvimbo yeVirtual Power Plant, ichigonesa kuwana mari kuburikidza nemisika inotonga mafrequency.

Mhedziso

IyoChaja yeDC ye180kW ye240kW ine Smart Load Balancing yeCharging Hubsndiyo sarudzo chaiyo yezvivakwa zvemagetsi zvehunyanzvi.


Nguva yekutumira: Nyamavhuvhu-08-2026

Siya Mharidzo Yako:

Nyora meseji yako pano woitumira kwatiri