Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW
Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW
The Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW is a CE and UL certified integrated battery energy storage and DC fast charging system that combines 216kWh, 372kWh of LFP storage with 120kW / 240kW DC output. It buffers grid and solar energy to deliver high-power EV charging for commercial fleet and public charging hubs, cutting demand charges, supporting peak shaving and ensuring reliable rapid charging even on grid-constrained sites.
Core Advantages
- Integrated BESS + DC Charger – 216kWh, 372kWh LFP storage and 120kW / 240kW DC output in one cabinet.
- Peak Shaving & Demand Charge Cut – stores cheap energy, caps costly grid spikes.
- Solar-Ready Hybrid Operation – on-grid, off-grid and solar-plus-storage modes.
- LFP Safety & Long Life – automotive-grade cells, multi-level BMS, fire protection.
- OCPP Smart Management – OCPP 1.6J/2.0.1, remote control, dynamic load balancing.
- Outdoor-Rated & Certified – IP54/IP55, wide temperature range, CE/UL/IEC.
Product Highlights

Outdoor-Rated Durability and Global Certification
Built for harsh outdoor duty, the Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW carries an IP54/IP55 enclosure and a wide operating temperature window from sub-zero cold to desert heat, with corrosion-resistant construction for coastal and industrial sites. The station is engineered to international standards including CE, UL, IEC and relevant grid-connection and fire-safety codes, so it qualifies for projects and incentive programs worldwide. Robust thermal management keeps the battery and power electronics within safe limits under continuous cycling. For commercial fleet and public charging hubs, this rugged, certified design means dependable year-round operation, straightforward permitting and long-term asset value in almost any climate on earth.
Solar Integration and Off-Grid Resilience
The Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW is solar-ready, accepting photovoltaic input so sites charge electric vehicles directly from clean on-site generation. Surplus daytime solar is stored in the BESS and released to charge vehicles after sunset or during peak tariff windows, maximizing self-consumption and renewable usage. In grid-weak or off-grid locations the battery and solar combination guarantees continuous fast charging where mains power is limited or absent. For commercial fleet and public charging hubs, this hybrid operation reduces carbon footprint, cuts reliance on diesel generators and delivers energy independence while maintaining dependable DC charging output around the clock, every day.


After-Sales Support and OEM ODM Service
MIDA backs the Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW with comprehensive after-sales support, including a multi-year warranty, global spare-parts availability and remote plus on-site technical service. Engineering teams assist with system sizing, grid-connection studies, installation guidance and commissioning to shorten project timelines. Full OEM and ODM capability lets distributors and developers customize enclosure styling, branding, connector configuration, battery capacity and software features to match their market. From first enquiry through years of operation, this partnership approach gives buyers of commercial fleet and public charging hubs a bankable supplier, predictable total cost of ownership and a storage-and-charging solution tailored precisely to their commercial requirements and growth plans.
Integrated BESS and DC Charging Architecture
The Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW merges a high-density LFP battery pack with a bidirectional power conversion system and a DC fast charging stage inside one weatherproof enclosure. By buffering grid energy in the battery, the station delivers burst charging power far above the site grid connection, so operators add fast charging to constrained locations without costly transformer upgrades. The integrated BESS smooths load, shaves peaks and stores cheap off-peak or solar energy for use during demand spikes. This architecture turns any commercial fleet and public charging hubs into a resilient, grid-friendly charging hub that keeps vehicles moving while protecting the local distribution network from overload.


Modular Scalability and Flexible Deployment
The Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW uses a modular design so battery capacity and charging power scale to match site demand and budget. Containerized and cabinet formats support quick installation, and additional modules expand energy or power as traffic grows, protecting the initial investment. Standardized interfaces simplify commissioning, maintenance and future upgrades, while the compact footprint suits sites where space is tight. Whether deployed as a single unit or a networked fleet of stations, this scalable platform lets operators of commercial fleet and public charging hubs roll out charging infrastructure in phases, add capacity on demand and standardize hardware across an entire portfolio with ease.
LFP Battery Safety and Long Cycle Life
At the core of the Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW is an automotive-grade lithium iron phosphate battery chosen for thermal stability, long cycle life and safe operation. A multi-level battery management system supervises cell voltage, current and temperature, balancing cells and isolating faults before they escalate. The design targets thousands of full cycles with slow capacity fade, supporting a long service life under daily cycling. Integrated fire detection, aerosol suppression and compartment isolation meet strict safety standards, giving operators of commercial fleet and public charging hubs confidence that the storage system will perform reliably and safely across many years of demanding commercial duty.

Product Specifications
| Battery Capacity | 216kWh (configurable) | DC Output Power | 120kW (configurable) |
| Battery Type | LFP (LiFePO4) | Output Voltage | 150-1000V DC |
| Connectors | CCS2 standard; CCS1/GB-T/CHAdeMO/NACS optional | Protocol | OCPP 1.6J / 2.0.1 |
| Grid Input | 3-phase 380/400V AC; solar PV ready | Operation Modes | On-grid / Off-grid / Hybrid |
| Protection | IP54/IP55, IK10 | Temperature | -30°C to +55°C |
| Safety | BMS, fire suppression, insulation monitoring | Certification | CE, UL, IEC, RoHS |
Application Scenarios
The Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW is deployed across commercial fleet and public charging hubs, highway corridors, logistics and bus depots, commercial car parks, and renewable microgrids. Explore related MIDA storage and charging solutions: 120KW Solar DC EV Charger BESS 261KWH PV Energy 120KWH 60KW BESS EV Charging Station Solar Integration Commercial 200KWH 120KW Intelligent Solar Storage EV Charging System Remote Solar BESS Energy Storage Solution 120KWH 522KWH Integrated With.
Frequently Asked Questions (FAQ)
How many vehicles can the 216kWh 120kW station charge per day?
Daily throughput of the 216kWh 120kW system depends on vehicle battery size and arrival pattern, but the 216kWh storage plus continuous grid and solar recharge lets the station support repeated 120kW charging sessions across the day. The energy management system schedules battery dispatch to maximize sessions while protecting cell life.
What is the configuration of the 120kW 241kWh BESS EV charging system?
The 120kW 241kWh configuration pairs a 241kWh LFP battery with a 120kW DC charging output in one integrated cabinet. The battery buffers grid and solar energy so the station delivers 120kW fast charging even where the grid connection is limited, making it ideal for peak shaving, demand charge reduction and reliable rapid EV charging at commercial and fleet sites.
How much grid power does the 50kW 93kWh system need?
Because the 93kWh battery supplies the charging peaks, the 50kW 93kWh unit draws a much smaller, steadier load from the grid than a 50kW charger alone. It stores energy during off-peak hours or from solar and discharges it during charging sessions, so sites can add fast charging without expensive transformer or grid upgrades.
What is the configuration of the 418kWh 200kW BESS EV charging system?
The 418kWh 200kW configuration pairs a 418kWh LFP battery with a 200kW DC charging output in one integrated cabinet. The battery buffers grid and solar energy so the station delivers 200kW fast charging even where the grid connection is limited, making it ideal for peak shaving, demand charge reduction and reliable rapid EV charging at commercial and fleet sites.
How much grid power does the 960kWh 400kW system need?
Because the 960kWh battery supplies the charging peaks, the 960kWh 400kW unit draws a much smaller, steadier load from the grid than a 400kW charger alone. It stores energy during off-peak hours or from solar and discharges it during charging sessions, so sites can add fast charging without expensive transformer or grid upgrades.
How much grid power does the 372kWh 240kW system need?
Because the 372kWh battery supplies the charging peaks, the 372kWh 240kW unit draws a much smaller, steadier load from the grid than a 240kW charger alone. It stores energy during off-peak hours or from solar and discharges it during charging sessions, so sites can add fast charging without expensive transformer or grid upgrades.
What is the configuration of the 120kWh 60kW BESS EV charging system?
The 120kWh 60kW configuration pairs a 120kWh LFP battery with a 60kW DC charging output in one integrated cabinet. The battery buffers grid and solar energy so the station delivers 60kW fast charging even where the grid connection is limited, making it ideal for peak shaving, demand charge reduction and reliable rapid EV charging at commercial and fleet sites.
How many vehicles can the 522kWh 240kW station charge per day?
Daily throughput of the 522kWh 240kW system depends on vehicle battery size and arrival pattern, but the 522kWh storage plus continuous grid and solar recharge lets the station support repeated 240kW charging sessions across the day. The energy management system schedules battery dispatch to maximize sessions while protecting cell life.
After-Sales Advantages
MIDA supports the Advanced Hybridized BESS Battery Storage EV Charging System LFP Grid 216kWh 120kW 372kWh 240kW with a multi-year warranty, global spare parts, remote diagnostics and on-site service, plus full OEM/ODM customization of capacity, connectors, enclosure and software. Engineering support covers sizing, grid-connection studies and commissioning for fast, bankable project delivery.
Portable EV Charger
Home EV Wallbox
DC Charger Station
BESS Charging Station
V2G V2H V2V V2L
EV Charging Module
DC Charging Connector
EV Accessories
