head_banner

150kW 240kW CCS2 Dual Gun DC Charger Station with OCPP 2.0.1

150kW 240kW CCS2 Dual Gun DC Charger Station with OCPP 2.0.1

In the rapidly maturing electric vehicle (EV) market, the requirements for charging infrastructure are shifting from simple “power delivery” to sophisticated “energy management.” As the global standard for high-speed DC charging in Europe, Asia, and increasingly Oceania, the CCS2 (Combined Charging System Type 2) interface is at the heart of this evolution. To meet the demands of high-traffic environments, fleet depots, and highway corridors, MIDA Power (迈依达) has developed its most advanced charging platform to date: the 150kW and 240kW CCS2 Dual Gun DC Charger series, natively equipped with the revolutionary OCPP 2.0.1 communication protocol.

1. The Electrification of Logistics: A Global Commercial Imperative

In the high-stakes world of last-mile delivery and heavy-duty logistics, the transition from internal combustion engines to electric powertrains is no longer optional. MIDA Power, with its decade of engineering excellence, is at the forefront of this revolution with the 150kW 240kW CCS2 Dual Gun DC Charger Station with OCPP 2.0.1.

Logistics hubs present a unique environment where downtime is direct revenue loss. The 150kW 240kW CCS2 Dual Gun DC Charger Station with OCPP 2.0.1 is engineered to meet the grueling duty cycles of urban delivery hubs, airport cargo terminals, and sea-port logistics corridors. By utilizing a 1000V high-voltage platform, MIDA ensures that next-generation electric vans and heavy trucks spend less time at the dispenser and more time on the road.

2. Technical Architecture: Inside the MIDA Power Stack

2.1 SiC MOSFET Topology and Efficiency

Traditional DC chargers often suffer from efficiency drops at partial loads. MIDA’s 150kW 240kW CCS2 Dual Gun DC Charger Station with OCPP 2.0.1 utilizes a multi-phase Silicon Carbide (SiC) MOSFET topology. Unlike standard IGBT-based systems, SiC allows for higher switching frequencies (up to 100kHz), reducing switching losses by 30%. This architecture enables the 150kW 240kW CCS2 Dual Gun DC Charger Station with OCPP 2.0.1 to maintain a peak efficiency of 96.5%.

150kW 240kW CCS2 Dual Gun DC Charger Station with OCPP 2.0.1


TECHNICAL APPENDIX: The MIDA Power Infrastructure Definitive White Paper

This appendix serves as a comprehensive technical foundation for the MIDA Power DC Fast Charging series. It provides CPOs (Charge Point Operators), fleet managers, and infrastructure investors with an in-depth understanding of the hardware, software, and regulatory frameworks that define MIDA’s 2026 product lineup.

I. Hardware Architecture: The Physics of High-Efficiency Conversion

At the core of every MIDA DC station is a modular power conversion stack utilizing the latest in wide-bandgap semiconductor technology. Our transition from traditional Silicon IGBTs to Silicon Carbide (SiC) MOSFETs represents a paradigm shift in energy density and thermal resilience.

1.1 SiC MOSFET Topology and LLC Resonant Converters

MIDA’s 30kW and 40kW power modules utilize a Phase-Shifted Full-Bridge (PSFB) combined with an LLC Resonant Converter stage. This configuration enables Zero Voltage Switching (ZVS) across the entire load spectrum. By eliminating switching losses during the turn-on phase, we achieve a peak conversion efficiency of 96.5%. The use of SiC materials allows for switching frequencies exceeding 100kHz, which significantly reduces the physical volume of magnetic components like high-frequency transformers and inductors, leading to a more compact cabinet footprint without compromising power output.

1.2 Isolated Air-Duct Cooling & Thermal Management

In industrial and commercial environments, electronic failure is most often caused by environmental contamination. MIDA engineering has pioneered the “Isolated Air-Duct” design. The internal chamber is hermetically divided: the power semiconductors and magnetics are cooled via a dedicated high-pressure wind tunnel, while the control logic, communication modules, and HMI are housed in a sealed, dust-free compartment. This ensures that even in IP54 or IP55-rated outdoor installations, conductive dust or moisture cannot bridge the high-voltage busbars.

II. Intelligence Layer: The AI-DES Energy Scheduling Algorithm

Modern charging is no longer just about delivering raw kilowatts; it is about intelligent energy orchestration. MIDA’s proprietary AI-DES (AI-Dynamic Energy Scheduling) platform operates on a three-tier logical framework:

  • Tier 1: Grid-Edge Responsiveness: The charger monitors local grid frequency and voltage transients at a sampling rate of 10kHz. If a grid instability is detected, the AI-DES system can throttle output within 20ms to prevent local circuit breaker trips, acting as a buffer for the utility provider.
  • Tier 2: Vehicle-Centric Optimization: Utilizing ISO 15118 “Plug & Charge” telemetry, the AI-DES system negotiates the optimal charging curve with the vehicle’s BMS. It accounts for battery temperature, state-of-health (SoH), and internal resistance to prevent premature aging of the lithium cells.
  • Tier 3: Economic Fleet Management: For large-scale depots, the system integrates with energy spot markets. It prioritizes charging during low-tariff windows and can utilize internal Battery Energy Storage Systems (BESS) to perform “Peak Shaving,” avoiding the high demand charges imposed by utilities during peak hours.

Post time: Aug-08-2026

Leave Your Message:

Write your message here and send it to us